← Simulation Lab

🚰 Size a pipe and pump

Civil & Mechanical

A village tank 20 m up is filled from a well. Pick the pipe size and material, and see velocity, friction loss and the pump power needed. Small pipes are cheap but waste energy forever.

⭐ Level 1: Trainee0 XP · next level at 300
🎯 10 L/s, 300 m of pipe, 20 m lift: keep velocity 0.6–2 m/s and pump power under 4.5 kW.
Controls
Results
Water velocity✗ 3.01 m/s (aim 0.6–2)
Friction loss42.5 m of head
Total head62.5 m
Pump power9.44 kW

Too fast: friction, noise and water hammer. Use a bigger pipe.

📘 How it works

Friction loss rises with the square of velocity and falls steeply with diameter. A slightly bigger pipe costs more once but saves pump energy every day for 20 years.

v = Q ÷ (πD²/4) · hf = f·(L/D)·v²/2g (Swamee–Jain f) · Power = ρgQH ÷ η, η = 0.65A simplified textbook model for learning. Real designs follow the full codes and standards.