♨️ Size a heat exchanger
Chemical & ProcessHot effluent at a dyeing unit can preheat boiler feed water (cold side in at 30 °C). Choose flows, the target and the flow arrangement, and find the area needed. Bigger area costs more.
⭐ Level 1: Trainee0 XP · next level at 300
Heat transferred251 kW
Hot side out60 °C
LMTD—
Area needed✗ impossible
Impossible: the cold side cannot get hotter than the hot side at that end (temperature cross). Try counter-flow or a lower target.
📘 How it works
Heat moves from hot to cold in proportion to area and the log-mean temperature difference (LMTD). Counter-flow keeps a temperature difference all along the exchanger, so it needs less area and can heat the cold side past the hot outlet.
Q = ṁc·cp·(Tc,out − Tc,in) · A = Q ÷ (U · LMTD), U = 800 W/m²K · LMTD = (ΔT1 − ΔT2) ÷ ln(ΔT1/ΔT2)A simplified textbook model for learning. Real designs follow the full codes and standards.