โ Heat Transfer learning pathHeat Transfer ยท Module 8 of 10
Transient conduction
Heating and cooling over time.
๐ Key ideas
- Transient (unsteady) conduction: temperatures change with time.
- Lumped capacitance method applies when Biot number Bi = hLc/k is below about 0.1 (uniform internal temperature).
- Lumped solution: (T - Tinf)/(Ti - Tinf) = exp(-t/tau), tau = rho c V / (h A).
- Time constant tau shows how quickly a body responds.
- Thermocouples are made small for fast response (small tau).
๐ก Real-life example: Like a small metal spoon in hot tea heating quickly and evenly, while a thick block takes longer.
Transient conductionConduction with time-varying temperature
Biot numberInternal conduction vs surface convection resistance
Lumped capacitanceAssumes uniform temperature inside a body
Time constantCharacteristic response time