โ Heat Transfer learning pathHeat Transfer ยท Module 3 of 10
Conduction in cylinders and composite systems
Pipes, insulation and contact resistance.
๐ Key ideas
- For a cylinder: R = ln(r2/r1) / (2 pi k L).
- Insulated pipes add resistances of pipe wall, insulation and outer convection.
- Critical radius of insulation (cylinder) = k / h; below it, adding insulation can increase heat loss.
- Contact resistance occurs at imperfect joints between surfaces.
- Thermal paste reduces contact resistance between chips and heat sinks.
๐ก Real-life example: Like lagging a hot water pipe: insulation slows heat loss, but for very thin wires a little insulation can actually help cooling.
Cylindrical resistanceln(r2/r1)/(2 pi k L)
Critical radiusk/h for cylinders
Contact resistanceResistance at imperfect joints
Thermal pasteMaterial filling gaps for better contact