โ Control Systems learning pathControl Systems ยท Module 5 of 10
Steady-state error
System type and error constants.
๐ Key ideas
- Steady-state error is the error left after transients die out.
- System type = number of pure integrators (poles at s = 0) in the open-loop G(s)H(s).
- Position constant Kp = lim G(s) as s -> 0; step error = 1/(1 + Kp).
- Velocity constant Kv = lim s G(s); ramp error = 1/Kv.
- Adding an integrator (type increases) removes step error but may reduce stability.
๐ก Real-life example: An integrator is like a stubborn helper who keeps pushing harder as long as any error remains, until it is exactly zero.
Steady-state errorError remaining after the transient ends
System typeNumber of open-loop poles at the origin
Position error constantKp = G(0)
Velocity error constantKv = lim s G(s) as s -> 0